Name the unit and say how it is powered. A plug in supply wants a receptacle within reach of its lead. A direct wire or J-box unit wants a junction box, a supply cable and a termination, which is line voltage work and therefore the electrician's, under the product documentation, local code and any NEC requirements that apply. The EnoLED 24V ELD non dimmable supply comes in plug in and direct wire forms (verify its rated output, input voltage and mounting requirements before you rely on them).
Position matters as much as the model number. Drivers want air around them, service access that avoids cutting a finished surface, and an enclosure suited to the conditions. Mark the spot in pencil on the framing. Settling it on install day, with the ceiling half closed, buries supplies above drywall. Read the LED power supply range with mounting method in mind, not wattage alone.
Whether it dims, and by what method
Say plainly whether the system is meant to dim, then name the route, because dimming belongs to the whole chain rather than to the tape. Some drivers are non dimmable by design. Others answer to one protocol and ignore the rest. The broad routes are a phase cut dimmer at the wall feeding a compatible driver, a low voltage controller between driver and strip, and a driver with dimming built in.
Whichever route you choose, compatibility across strip, driver, dimmer and controller has to be confirmed in the documentation, minimum and maximum load included, then proven on the bench before trim goes back on. Keep the methods apart: unless both sets of instructions allow it, a smart low voltage controller and a phase cut wall device do not belong on one circuit. If a wall dimmer is in the plan, say so at quote stage, since it changes the box and the cable.
Zones, switch locations and run lengths
Count the zones. Each area you want to switch or set on its own is a separate control path, often a separate driver output or channel. A multi channel unit such as the EnoSync Hub5 controller handles several from one point (verify its channel count, per channel current and supported strip types before you rely on them).
Then mark where the switches belong: which door, what height, which zone each owns. Run lengths come last. Each product publishes a maximum length before voltage drop shows at the far end (verify that figure per product), so a long wall may need feeding from both ends, or splitting into two runs returning to the driver in parallel rather than chained one behind the other.
What to hand over when you brief an electrician for an LED strip project
One page carries it: product links for strip, driver, controller and channel; the voltage; connected watts per run beside the driver capacity; the dimming method; a zone list with switch positions; run lengths with feed points; and the IP rating needed at each location, written as the exact rating rather than the word waterproof.
Then add the line that prevents arguments later, which parts you supply and which the electrician does. Trades specifying these parts regularly can register through the PRO Club page.